Specification
According to the project and details,
- Aypan DU profiles made of galvanized steel sheet according to TS EN 14195 must be fixed to the base and ceiling by using Aypan screws and plastic dowels at 60 cm intervals.
- Aypan sound insulation tape should be affixed behind the Aypan DC profiles (made in accordance with TS EN 1495) to be attached to DU and side walls.
- The DC profiles should be dimensioned according to the wall height (cut if necessary).
- The DC profiles must be inserted between the DU profiles at 40 or 60 cm intervals.
- If desired, rockwool plates of appropriate thickness and density should be placed between the DC profiles.
- Aypan should be cut and sized and fixed to the profiles with 25 mm drywall screws (maximum 30 cm spacing). Aygips joint filler plaster should be pre-filled into gaps more than 3mm. Screw heads should be covered with Aygips grouting plaster. Joint tape should be adhered to Aypan joints.
- A partition wall should be formed by applying Aygips joint filler plaster on the joint tape.
The price of 1 m2 including all kinds of materials and losses, loading at the customer, horizontal and vertical transportation, unloading and contractor profit and general expenses.
Quantities
Prodoct Code | Material Name | 40 cm** | 60 cm** | Unit |
AL125BY250 | AYPAN (12,5 mm) | 2,00 | 2,00 | m² |
AK50NDC300 | AYPAN DC50 Profile | 2,80 | 2,00 | m |
AK50NDU300 | AYPAN DU50 Profile | 0,80 | 0,80 | m |
BN050YB025 | AYPAN Noice Reduction Tape | 1,30 | 1,30 | m |
AB048DV145 | AYPAN Plastic Dowel and Pan Head Screw Set | 2,20 | 2,20 | pcs |
AB035BV025 | AYPAN Drywall Screw 3,5x25 mm | 38,00 | 30,00 | pcs |
BN050DB090 | AYPAN Joınt Tape | 2,80 | 2,80 | m |
AG001DD025 | AYGIPS Joing Filling Plaster | 0,80 | 0,80 | kg |
Rock wool | 1,00 | 1,00 | m² | |
AG001ST025 | AYGIPS Satin Finishing Plaster | For each one mm | kg | |
AK022DP270 | AYPAN Perforated Corner Profile | As per project | m | |
A DOOR SYSTEM ANALYZE | ||||
Material Name | Quantities | Unit | ||
Door Supported Stud | ||||
L Bracket Somun Bolt Set | ||||
Steel anchor | ||||
*Without wastage | ||||
**DC Profile axis gap | ||||
***Ask to technical office for choosing different sizes profiles. | ||||
***Based on 4X2,5 mt wall measurements. |
Performance
Non-carrier partition wall system. It is formed by screwing one layer of Aypan on both sides of a single metal frame (Aypan DC) made of galvanized steel sheet.
- It can be used in all kinds of buildings such as office, hospital, hotel, residence.
- Max. It can be applied to a height of 5.45 m.
- The average weight of the system is 23-26 kg / m2. The fire resistance is F30 with Aypan® Red.
- To improve the sound and heat performance of the system, insulation boards such as rock wool can be placed between the profiles. When rockwool is used, the sound insulation performance of the system is between 40-47 dB.
- Aypan Sound Insulation Tape should be adhered to the profile backs on the surfaces where the flooring and wall intersect, and measures should be taken against sound bridges. The gap between the profiles can be used as the installation passage.